Assessment Year | 1995 |
---|---|
Principal Product | Sodium Silicate |
NAICS |
n/a
|
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 15 |
Plant Area |
30,000
ft2
|
Annual Production | 36,500
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $62,625 | 1,068,875 |
kWh
|
$0.059 |
Natural Gas | $631,507 | 217,873 |
MMBtu
|
$2.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $124,065 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,895 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,890 | $3,400 |
$(-190.0)
(-4,396)
kWh
|
- |
$4,080
-
Tgal
|
|
02 | 2.2192: Use heat exchange fluids instead of steam in pipeline tracing systems | $3,045 | $3,100 | - |
$3,045
-
MMBtu
|
- | |
03 | 2.2135: Repair and eliminate steam leaks | $1,850 | $300 | - |
$1,850
-
MMBtu
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $890 | $3,980 |
$890
11,137
kWh
|
- | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $113,700 | $200,000 | - |
$113,700
-
MMBtu
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $690 | $1,370 |
$690
15,240
kWh
|
- | - | |
TOTAL RECOMMENDED | $124,065 | $212,150 |
$1,390
21,981
kWh
|
$118,595
-
MMBtu
|
$4,080
-
Tgal
|
||
TOTAL IMPLEMENTED | $4,895 | $3,400 | - |
$4,895
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs