| Assessment Year | 2007 |
|---|---|
| Principal Product | Pipeline Accessories |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
32,000
ft2
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,798 | 301,244 |
kWh
|
$0.079 |
| Electricity Demand | $5,385 | 6 |
kW-mo/yr
|
$897.50 |
| Electricity Fees | $1,600 | - |
|
- |
| Natural Gas | $12,238 | 1,010 |
MMBtu
|
$12.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,964 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,051 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,971 | $2,080 |
$1,869
23,655
kWh
|
$102 | - | - | |
| 02 | 4.611: Begin a practice of predictive / preventative maintenance | $1,721 | $150 |
$210
2,652
kWh
|
$11 | - | $1,500 | |
| 03 | 2.2511: Insulate bare equipment | $775 | $438 | - | - |
$775
-
MMBtu
|
- | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $567 | $825 |
$537
6,801
kWh
|
$30 | - | - | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $437 | $471 |
$414
5,245
kWh
|
$23 | - | - | |
| 06 | 2.7134: Use photocell controls | $276 | $90 |
$262
3,319
kWh
|
$14 | - | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $170 | $30 |
$161
2,035
kWh
|
$9 | - | - | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $47 | $183 |
$45
567
kWh
|
$2 | - | - | |
| TOTAL RECOMMENDED | $5,964 | $4,267 |
$3,498
44,274
kWh
|
$191 |
$775
-
MMBtu
|
$1,500 | ||
| TOTAL IMPLEMENTED | $1,051 | $528 |
$262
3,319
kWh
|
$14 |
$775
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs