Assessment Year | 2007 |
---|---|
Principal Product | fryers |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
295,000
ft2
|
Annual Production | 80,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $310,995 | 10,641,450 |
kWh
|
$0.029 |
Electricity Demand | $268,682 | 24,120 |
kW-mo/yr
|
$11.14 |
Electricity Fees | $19,202 | - |
|
- |
Natural Gas | $142,715 | 15,632 |
MMBtu
|
$9.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $141,391 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $136,256 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $80,705 | $745 |
$78,127
2,723,136
kWh
|
- | $2,578 | - | |
02 | 2.2511: Insulate bare equipment | $29,800 | $1,169 |
$28,848
1,005,495
kWh
|
- | $952 | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $12,804 | $1,200 |
$7,527
262,362
kWh
|
$4,868
-
kW-mo/yr
|
$409 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,933 | $4,400 |
$6,426
223,965
kWh
|
$4,158
-
kW-mo/yr
|
$349 | - | |
05 | 4.611: Begin a practice of predictive / preventative maintenance | $4,110 | $3,605 | - | - | - | $4,110 | |
06 | 2.4239: Eliminate or reduce compressed air usage | $2,014 | $2,973 |
$1,950
67,952
kWh
|
- | $64 | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $793 | $1,670 |
$501
17,472
kWh
|
$267
-
kW-mo/yr
|
$25 | - | |
08 | 2.7135: Install occupancy sensors | $174 | $90 |
$168
5,871
kWh
|
- | $6 | - | |
09 | 2.7134: Use photocell controls | $58 | $60 |
$56
1,954
kWh
|
- | $2 | - | |
TOTAL RECOMMENDED | $141,391 | $15,912 |
$123,603
4,308,207
kWh
|
$9,293
-
kW-mo/yr
|
$4,385 | $4,110 | ||
TOTAL IMPLEMENTED | $136,256 | $10,487 |
$122,878
4,282,910
kWh
|
$9,026
-
kW-mo/yr
|
$4,352 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs