| Assessment Year | 2007 |
|---|---|
| Principal Product | fryers |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
150,000
ft2
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 6,300
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,086 | 4,864,000 |
kWh
|
$0.029 |
| Electricity Demand | $129,852 | 12,048 |
kW-mo/yr
|
$10.78 |
| Electricity Fees | $8,875 | - |
|
- |
| Natural Gas | $7,332 | 563 |
MMBtu
|
$13.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $52,281 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $47,986 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $37,538 | $74,520 |
$36,339
1,270,691
kWh
|
- | $1,199 | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $9,733 | $357 |
$9,422
329,443
kWh
|
- | $311 | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,583 | $1,225 |
$333
11,651
kWh
|
$172
-
kW-mo/yr
|
$17 | $1,061 | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $715 | $345 |
$228
7,956
kWh
|
$464
-
kW-mo/yr
|
$23 | - | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $313 | $623 |
$200
6,989
kWh
|
$103
-
kW-mo/yr
|
$10 | - | |
| 06 | 2.7135: Install occupancy sensors | $59 | $60 |
$57
1,987
kWh
|
- | $2 | - | |
| 07 | 4.611: Begin a practice of predictive / preventative maintenance | $2,340 | $1,318 | - | - | - | $2,340 | |
| TOTAL RECOMMENDED | $52,281 | $78,448 |
$46,579
1,628,717
kWh
|
$739
-
kW-mo/yr
|
$1,562 | $3,401 | ||
| TOTAL IMPLEMENTED | $47,986 | $75,222 |
$45,989
1,608,090
kWh
|
$464
-
kW-mo/yr
|
$1,533 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs