Assessment Year | 2006 |
---|---|
Principal Product | Wood chips and wood mill |
NAICS | 321113: Sawmills |
SIC | 2426: Hardwood Dimension and Flooring Mills |
Sales Range | $10 M to 50M |
# of Employees | 37 |
Plant Area |
5,000
ft2
|
Annual Production | 350,000
ton
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $229,436 | 4,965,600 |
kWh
|
$0.046 |
Electricity Demand | $89,496 | 14,916 |
kW-mo/yr
|
$6.00 |
Electricity Fees | $12,104 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,757 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,569 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $2,380 | $400 |
$62
1,331
kWh
|
$2 | $816 | $1,500 | |
02 | 2.7224: Reduce space conditioning during non-working hours | $2,013 | $330 |
$1,939
41,953
kWh
|
$74 | - | - | |
03 | 2.7134: Use photocell controls | $882 | $120 |
$850
18,399
kWh
|
$32 | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $838 | $30 |
$807
17,463
kWh
|
$31 | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $456 | $280 |
$439
9,507
kWh
|
$17 | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $139 | $105 |
$46
999
kWh
|
$2 | $91 | - | |
07 | 2.7135: Install occupancy sensors | $49 | $120 |
$47
1,007
kWh
|
$2 | - | - | |
TOTAL RECOMMENDED | $6,757 | $1,385 |
$4,190
90,659
kWh
|
$160 | $907 | $1,500 | ||
TOTAL IMPLEMENTED | $6,569 | $1,160 |
$4,097
88,653
kWh
|
$156 | $816 | $1,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |