ITAC Assessment: LL0234
ITAC logo
ITAC Assessment: LL0234
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Rice Drying
NAICS 311212: Rice Milling
SIC 2044: Rice Milling
Sales Range $10
M
to 50
M
# of Employees 62
Plant Area 127,000
ft2
Annual Production 22,500,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $307,876 11,689,696
kWh
Electricity Demand $211,960 24,290
kW-mo/yr
Electricity Fees $4,482 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $130,817 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $97,828

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7111: Reduce illumination to minimum necessary levels $24,789 - $17,440
662,094
kWh
$7,349
-
kW-mo/yr
- - - -
02 2.4239: Eliminate or reduce compressed air usage $69,333 $500 - - $182 $69,151
-
MMBtu
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,415 $1,250 $3,381
128,351
kWh
- $34 - - -
04 2.7135: Install occupancy sensors $1,630 - $1,614
61,279
kWh
- $16 - - -
05 2.7134: Use photocell controls $501 $100 $496
18,814
kWh
- $5 - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $136 $200 $135
5,110
kWh
- $1 - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $393 $300 $88
3,329
kWh
- $1 - $304 -
08 4.611: Begin a practice of predictive / preventative maintenance $24,050 $7,000 - - - - $21,550 $2,500
09 4.611: Begin a practice of predictive / preventative maintenance $6,570 - - - - - $6,570 -
TOTAL RECOMMENDED $130,817 $9,350 $23,154
878,977
kWh
$7,349
-
kW-mo/yr
$239 $69,151
-
MMBtu
$28,424 $2,500
TOTAL IMPLEMENTED $97,828 $9,350 $4,100
155,604
kWh
- $223 $69,151
-
MMBtu
$21,854 $2,500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs