Assessment Year | 2005 |
---|---|
Principal Product | Children\\\\\\\'s textiles |
NAICS | 315210: Cut and Sew Apparel Contractors |
SIC | 2395: Pleating, Decorative and Novelty Stitching, and Tucking for the Trade |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
150,000
ft2
|
Annual Production | 5,600,000
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $49,481 | 597,550 |
kWh
|
$0.083 |
Electricity Demand | $19,084 | 5,256 |
kW-mo/yr
|
$3.63 |
Electricity Fees | $2,240 | - |
|
- |
Natural Gas | $7,483 | 582 |
MMBtu
|
$12.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,902 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,460 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $14,286 | - |
$13,830
167,004
kWh
|
- | $456 | - | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $8,439 | - | - |
$8,169
-
kW-mo/yr
|
$270 | - | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $4,224 | $170 |
$4,089
49,384
kWh
|
- | $135 | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,236 | $735 |
$579
6,990
kWh
|
- | $19 | - | $638 | - | |
05 | 2.7134: Use photocell controls | $337 | - |
$326
3,934
kWh
|
- | $11 | - | - | - | |
06 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,000 | $25 | - | - | - |
$1,000
-
lb
|
- | - | |
07 | 4.611: Begin a practice of predictive / preventative maintenance | $16,500 | - | - | - | - | - | $14,000 | $2,500 | |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $2,880 | - | - | - | - | - | $2,880 | - | |
TOTAL RECOMMENDED | $48,902 | $930 |
$18,824
227,312
kWh
|
$8,169
-
kW-mo/yr
|
$891 |
$1,000
-
lb
|
$17,518 | $2,500 | ||
TOTAL IMPLEMENTED | $6,460 | $930 |
$4,668
56,374
kWh
|
- | $154 |
$1,000
-
lb
|
$638 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs