Assessment Year 2004
Principal Product ship and repair
NAICS 336611: Ship Building and Repairing
SIC 3731: Ship Building and Repairing
Sales Range $5
M
to 10
M
# of Employees 40
Plant Area 60,000
ft2
Annual Production 54
pieces
Production Hrs. Annual 3,510
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,501 1,473,546
kWh
Electricity Demand $25,765 8,441
kW-mo/yr
Electricity Fees $3,815 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,461 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,428

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7111: Reduce illumination to minimum necessary levels $4,929 $825 $3,805
65,578
kWh
$972
-
kW-mo/yr
$152 - -
02 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $2,415 $895 $2,336
40,256
kWh
- $79 - -
03 2.7134: Use photocell controls $899 $30 $869
14,976
kWh
- $30 - -
04 2.7224: Reduce space conditioning during non-working hours $778 $990 $752
12,961
kWh
- $26 - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $755 $525 $290
4,993
kWh
- $10 $455 -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $754 $1,120 $729
12,571
kWh
- $25 - -
07 2.4231: Reduce the pressure of compressed air to the minimum required $261 $30 $252
4,342
kWh
- $9 - -
08 2.7134: Use photocell controls $170 $270 $164
2,830
kWh
- $6 - -
09 4.611: Begin a practice of predictive / preventative maintenance $5,500 $1,050 - - - $3,000 $2,500
TOTAL RECOMMENDED $16,461 $5,735 $9,197
158,507
kWh
$972
-
kW-mo/yr
$337 $3,455 $2,500
TOTAL IMPLEMENTED $9,428 $3,170 $8,155
140,553
kWh
$972
-
kW-mo/yr
$301 - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs