Assessment Year | 2004 |
---|---|
Principal Product | ship and repair |
NAICS | 336612: Boat Building |
SIC | 3732: Boat Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
75,000
ft2
|
Annual Production | 10
pieces
|
Production Hrs. Annual | 5,616
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $166,007 | 2,721,619 |
kWh
|
$0.061 |
Electricity Demand | $62,375 | 9,287 |
kW-mo/yr
|
$6.72 |
Electricity Fees | $7,817 | - |
|
- |
Other Gas | $9,203 | 740 |
MMBtu
|
$12.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $148,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $135,292 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $104,709 | $19,500 |
$101,266
1,660,105
kWh
|
- | $3,443 | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $24,408 | $9,920 |
$23,605
386,966
kWh
|
- | $803 | - | - | - | |
03 | 2.1331: Burn a less expensive grade of fuel | $5,147 | $1,528 | - | - | - |
$5,147
-
MMBtu
|
- | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $4,154 | $507 |
$4,017
65,846
kWh
|
- | $137 | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,533 | $1,051 |
$601
9,986
kWh
|
- | $21 | - | $911 | - | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $687 | $270 |
$596
9,771
kWh
|
$68
-
kW-mo/yr
|
$23 | - | - | - | |
07 | 2.7135: Install occupancy sensors | $208 | $240 |
$201
3,296
kWh
|
- | $7 | - | - | - | |
08 | 2.7134: Use photocell controls | $133 | $90 |
$129
2,114
kWh
|
- | $4 | - | - | - | |
09 | 4.611: Begin a practice of predictive / preventative maintenance | $7,540 | $560 | - | - | - | - | $5,040 | $2,500 | |
TOTAL RECOMMENDED | $148,519 | $33,666 |
$130,415
2,138,084
kWh
|
$68
-
kW-mo/yr
|
$4,438 |
$5,147
-
MMBtu
|
$5,951 | $2,500 | ||
TOTAL IMPLEMENTED | $135,292 | $31,548 |
$125,797
2,062,252
kWh
|
$68
-
kW-mo/yr
|
$4,280 |
$5,147
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs