Assessment Year | 2004 |
---|---|
Principal Product | Plastic pipe |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
84,000
ft2
|
Annual Production | 90,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $583,465 | 18,396,651 |
kWh
|
$0.032 |
Electricity Demand | $204,354 | 31,733 |
kW-mo/yr
|
$6.44 |
Electricity Fees | $30,293 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $174,465 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $169,734 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $28,231 | $3,647 |
$27,197
857,424
kWh
|
- | $1,034 | - | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,510 | $8,280 |
$17,832
562,160
kWh
|
- | $678 | - | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,379 | $30 |
$3,849
121,349
kWh
|
$1,333
-
kW-mo/yr
|
$197 | - | - | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $4,403 | $789 |
$3,321
104,690
kWh
|
$921
-
kW-mo/yr
|
$161 | - | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $620 | $525 |
$158
4,993
kWh
|
- | $6 | $456 | - | - | - | |
06 | 2.2511: Insulate bare equipment | $328 | $401 |
$316
9,951
kWh
|
- | $12 | - | - | - | - | |
07 | 2.7134: Use photocell controls | $323 | $90 |
$311
9,796
kWh
|
- | $12 | - | - | - | - | |
08 | 2.7135: Install occupancy sensors | $160 | $150 |
$154
4,843
kWh
|
- | $6 | - | - | - | - | |
09 | 3.4154: Eliminate leaks in water lines and valves | $181 | $150 | - | - | - | - |
$181
-
Tgal
|
- | - | |
10 | 4.611: Begin a practice of predictive / preventative maintenance | $114,500 | $4,820 | - | - | - | - | - | $2,500 | $112,000 | |
11 | 4.611: Begin a practice of predictive / preventative maintenance | $1,830 | $1,790 | - | - | - | - | - | - | $1,830 | |
TOTAL RECOMMENDED | $174,465 | $20,672 |
$53,138
1,675,206
kWh
|
$2,254
-
kW-mo/yr
|
$2,106 | $456 |
$181
-
Tgal
|
$2,500 | $113,830 | ||
TOTAL IMPLEMENTED | $169,734 | $19,482 |
$49,501
1,560,565
kWh
|
$1,333
-
kW-mo/yr
|
$1,933 | $456 |
$181
-
Tgal
|
$2,500 | $113,830 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs