Assessment Year | 2004 |
---|---|
Principal Product | Chips |
NAICS | 311919: Other Snack Food Manufacturing |
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 94 |
Plant Area |
66,600
ft2
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 6,604
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $108,593 | 1,462,789 |
kWh
|
$0.074 |
Electricity Fees | $4,184 | - |
|
- |
Natural Gas | $226,769 | 36,440 |
MMBtu
|
$6.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,239 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,430 | $1,080 |
$6,189
83,358
kWh
|
$241 | - | - | - | - | |
02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $3,365 | $1,868 | - | - |
$3,365
-
MMBtu
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,158 | $30 |
$3,039
40,939
kWh
|
$119 | - | - | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,067 | $162 |
$1,989
26,795
kWh
|
$78 | - | - | - | - | |
05 | 2.7134: Use photocell controls | $555 | $120 |
$534
7,195
kWh
|
$21 | - | - | - | - | |
06 | 2.7135: Install occupancy sensors | $521 | $180 |
$501
6,754
kWh
|
$20 | - | - | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $393 | $245 |
$173
2,330
kWh
|
$7 | - | $213 | - | - | |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $4,750 | $1,820 | - | - | - | - | $2,500 | $2,250 | |
TOTAL RECOMMENDED | $21,239 | $5,505 |
$12,425
167,371
kWh
|
$486 |
$3,365
-
MMBtu
|
$213 | $2,500 | $2,250 | ||
TOTAL IMPLEMENTED | $11,180 | $2,900 |
$6,189
83,358
kWh
|
$241 | - | - | $2,500 | $2,250 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs