Assessment Year 2004
Principal Product boat/repair
NAICS 336611: Ship Building and Repairing
SIC 3731: Ship Building and Repairing
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 250,000
ft2
Annual Production 180
pieces
Production Hrs. Annual 5,148
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $173,342 3,097,193
kWh
Electricity Demand $49,246 12,311
kW-mo/yr
Electricity Fees $8,436 -
Natural Gas $944 204
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $106,981 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $86,117

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $69,470 $20,680 $66,927
1,196,762
kWh
$2,543 -
02 2.4239: Eliminate or reduce compressed air usage $14,991 $16,845 $14,442
258,033
kWh
$549 -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,972 $500 - - $9,972
04 2.4231: Reduce the pressure of compressed air to the minimum required $6,675 $30 $6,431
114,898
kWh
$244 -
05 2.7132: Install timers on light switches in little used areas $3,376 $135 $3,252
58,111
kWh
$124 -
06 2.7135: Install occupancy sensors $1,329 $390 $1,280
22,872
kWh
$49 -
07 2.7134: Use photocell controls $726 $150 $700
12,501
kWh
$26 -
08 2.7224: Reduce space conditioning during non-working hours $442 $198 $426
7,604
kWh
$16 -
TOTAL RECOMMENDED $106,981 $38,928 $93,458
1,670,781
kWh
$3,551 $9,972
TOTAL IMPLEMENTED $86,117 $21,210 $73,358
1,311,660
kWh
$2,787 $9,972
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs