Assessment Year | 2004 |
---|---|
Principal Product | boat/repair |
NAICS | 336611: Ship Building and Repairing |
SIC | 3731: Ship Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
60,000
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,315 | 1,365,048 |
kWh
|
$0.071 |
Electricity Demand | $14,035 | 4,895 |
kW-mo/yr
|
$2.87 |
Electricity Fees | $5,254 | - |
|
- |
Natural Gas | $849 | 81 |
MMBtu
|
$10.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,740 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,740 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $8,219 | $5,615 |
$7,843
111,147
kWh
|
- | $376 | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,772 | $3,240 |
$6,462
91,578
kWh
|
- | $310 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,084 | $30 |
$3,897
55,223
kWh
|
- | $187 | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,265 | $195 |
$1,756
24,891
kWh
|
$405
-
kW-mo/yr
|
$104 | - | |
05 | 2.7134: Use photocell controls | $1,522 | $300 |
$1,452
20,583
kWh
|
- | $70 | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $227 | $198 |
$217
3,072
kWh
|
- | $10 | - | |
07 | 2.7135: Install occupancy sensors | $151 | $90 |
$144
2,035
kWh
|
- | $7 | - | |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $2,500 | $60 | - | - | - | $2,500 | |
TOTAL RECOMMENDED | $25,740 | $9,728 |
$21,771
308,529
kWh
|
$405
-
kW-mo/yr
|
$1,064 | $2,500 | ||
TOTAL IMPLEMENTED | $25,740 | $9,728 |
$21,771
308,529
kWh
|
$405
-
kW-mo/yr
|
$1,064 | $2,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs