| Assessment Year | 2004 |
|---|---|
| Principal Product | Vegetable oil |
| NAICS | 311225: Fats and Oils Refining and Blending |
| SIC | 2079: Shortening, Table Oils, Margarine, and Other Edible Fats and Oils, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
68,200
ft2
|
| Annual Production | 116,666,667
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $274,346 | 5,941,497 |
kWh
|
$0.046 |
| Electricity Demand | $91,573 | 10,439 |
kW-mo/yr
|
$8.77 |
| Electricity Fees | $14,045 | - |
|
- |
| Natural Gas | $1,450,749 | 264,067 |
MMBtu
|
$5.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $271,637 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $248,706 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2135: Repair and eliminate steam leaks | $241,700 | $8,200 | - | - | - |
$241,700
-
MMBtu
|
- | - | |
| 02 | 2.2121: Increase amount of condensate returned | $16,796 | $25,635 | - | - | - |
$9,241
-
MMBtu
|
- |
$7,555
-
Tgal
|
|
| 03 | 2.7134: Use photocell controls | $5,421 | $180 |
$5,223
113,128
kWh
|
- | $198 | - | - | - | |
| 04 | 2.2511: Insulate bare equipment | $4,981 | $942 | - | - | - |
$4,981
-
MMBtu
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $1,121 | $395 | - | - | - |
$1,121
-
MMBtu
|
- | - | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $785 | $510 |
$598
12,950
kWh
|
$158
-
kW-mo/yr
|
$29 | - | - | - | |
| 07 | 2.7134: Use photocell controls | $369 | $120 |
$355
7,692
kWh
|
- | $14 | - | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $464 | $350 |
$154
3,329
kWh
|
- | $6 | - | $304 | - | |
| TOTAL RECOMMENDED | $271,637 | $36,332 |
$6,330
137,099
kWh
|
$158
-
kW-mo/yr
|
$247 |
$257,043
-
MMBtu
|
$304 |
$7,555
-
Tgal
|
||
| TOTAL IMPLEMENTED | $248,706 | $9,125 |
$5,377
116,457
kWh
|
- | $204 |
$242,821
-
MMBtu
|
$304 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs