Assessment Year | 2003 |
---|---|
Principal Product | Oil and lubricant addatives |
NAICS | 324191: Petroleum Lubricating Oil and Grease Manufacturing |
SIC | 2992: Lubricating Oils and Greases |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
4,356,000
ft2
|
Annual Production | 70,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Natural Gas | $9,781,506 | 2,756,129 |
MMBtu
|
$3.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,406,451 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,341,552 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $1,037,596 | $14,410 |
$1,037,596
-
MMBtu
|
- | - | |
02 | 2.2113: Repair or replace steam traps | $295,550 | $63,360 |
$295,550
-
MMBtu
|
- | - | |
03 | 2.2121: Increase amount of condensate returned | $55,698 | $230,000 | - | - | $55,698 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,201 | $3,240 |
$9,201
-
MMBtu
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,848 | $3,500 |
$3,813
-
MMBtu
|
$1,817 | $2,218 | |
06 | 2.7135: Install occupancy sensors | $292 | $26 |
$292
-
MMBtu
|
- | - | |
07 | 2.2511: Insulate bare equipment | $266 | $349 |
$266
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $1,406,451 | $314,885 |
$1,346,718
-
MMBtu
|
$1,817 | $57,916 | ||
TOTAL IMPLEMENTED | $1,341,552 | $81,645 |
$1,337,517
-
MMBtu
|
$1,817 | $2,218 | ||
Yearly Savings* | Imp'd Cost* | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs