| Assessment Year | 2003 |
|---|---|
| Principal Product | Oilfield Equipment |
| NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $100 M to 500M |
| # of Employees | 500 |
| Plant Area |
70,000
ft2
|
| Annual Production | 21,000
pieces
|
| Production Hrs. Annual | 5,824
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $296,629 | 4,492,372 |
kWh
|
$0.066 |
| Electricity Demand | $4,788 | 848 |
kW-mo/yr
|
$5.65 |
| Electricity Fees | $13,592 | - |
|
- |
| Natural Gas | $23,058 | 5,685 |
MMBtu
|
$4.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $98,092 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $50,631 | $4,551 |
$48,684
736,969
kWh
|
- | $1,947 | - | - | - | |
| 02 | 2.7135: Install occupancy sensors | $17,563 | $5,075 |
$16,890
255,673
kWh
|
- | $673 | - | - | - | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $4,307 | $10,605 | - | - | - |
$4,307
-
MMBtu
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,909 | $1,360 |
$4,721
71,463
kWh
|
- | $188 | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,798 | $900 |
$660
9,986
kWh
|
$79
-
kW-mo/yr
|
$30 | - | - | $1,029 | |
| 06 | 2.8112: Combine utility meters | $15,037 | - | - | - | $15,037 | - | - | - | |
| 07 | 4.611: Begin a practice of predictive / preventative maintenance | $1,928 | $786 | - | - | - | - | - | $1,928 | |
| 08 | 2.8112: Combine utility meters | $1,163 | - | - | - | - | - |
$1,163
-
Tgal
|
- | |
| 09 | 2.8112: Combine utility meters | $756 | - | - | - | - |
$756
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $98,092 | $23,277 |
$70,955
1,074,091
kWh
|
$79
-
kW-mo/yr
|
$17,875 |
$5,063
-
MMBtu
|
$1,163
-
Tgal
|
$2,957 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs