| Assessment Year | 2002 |
|---|---|
| Principal Product | Fire Trucks |
| NAICS |
n/a
|
| SIC | 3711: Motor Vehicles and Passenger Car Bodies |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
150,000
ft2
|
| Annual Production | 250
pieces
|
| Production Hrs. Annual | 4,602
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $54,710 | 2,274,750 |
kWh
|
$0.024 |
| Electricity Demand | $44,572 | 7,189 |
kW-mo/yr
|
$6.20 |
| Electricity Fees | $8,643 | - |
|
- |
| Natural Gas | $35,997 | 3,190 |
MMBtu
|
$11.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,870 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,671 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $6,951 | $9,520 | - |
$6,684
-
kW-mo/yr
|
$267 | |
| 02 | 2.7134: Use photocell controls | $3,964 | $416 |
$2,491
103,574
kWh
|
$1,321
-
kW-mo/yr
|
$152 | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $3,671 | - |
$1,918
79,743
kWh
|
$1,612
-
kW-mo/yr
|
$141 | |
| 04 | 2.7135: Install occupancy sensors | $762 | $78 |
$479
19,918
kWh
|
$254
-
kW-mo/yr
|
$29 | |
| 05 | 2.7134: Use photocell controls | $460 | $52 |
$287
11,951
kWh
|
$155
-
kW-mo/yr
|
$18 | |
| 06 | 2.7135: Install occupancy sensors | $312 | $52 |
$195
8,126
kWh
|
$105
-
kW-mo/yr
|
$12 | |
| 07 | 2.7135: Install occupancy sensors | $200 | $260 |
$87
3,628
kWh
|
$105
-
kW-mo/yr
|
$8 | |
| 08 | 2.7135: Install occupancy sensors | $198 | $52 |
$122
5,079
kWh
|
$68
-
kW-mo/yr
|
$8 | |
| 09 | 2.7135: Install occupancy sensors | $198 | $52 |
$122
5,079
kWh
|
$68
-
kW-mo/yr
|
$8 | |
| 10 | 2.7135: Install occupancy sensors | $154 | $52 |
$98
4,063
kWh
|
$50
-
kW-mo/yr
|
$6 | |
| TOTAL RECOMMENDED | $16,870 | $10,534 |
$5,799
241,161
kWh
|
$10,422
-
kW-mo/yr
|
$649 | ||
| TOTAL IMPLEMENTED | $3,671 | - |
$1,918
79,743
kWh
|
$1,612
-
kW-mo/yr
|
$141 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs