Plant Area |
250,000
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $400,546 | 9,725,750 |
kWh
|
$0.041 |
Electricity Demand | $87,694 | 15,944 |
kW-mo/yr
|
$5.50 |
Electricity Fees | $19,530 | - |
|
- |
Natural Gas | $185,977 | 26,043 |
MMBtu
|
$7.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,570 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,693 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $23,222 | $10,500 |
$22,329
542,220
kWh
|
- | $893 | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $17,996 | $32,600 | - | - | - |
$17,996
-
MMBtu
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $6,584 | - |
$5,249
127,476
kWh
|
$1,082
-
kW-mo/yr
|
$253 | - | |
04 | 2.3212: Optimize plant power factor | $5,475 | $10,500 | - |
$5,264
-
kW-mo/yr
|
$211 | - | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $3,293 | - |
$2,625
63,738
kWh
|
$541
-
kW-mo/yr
|
$127 | - | |
TOTAL RECOMMENDED | $56,570 | $53,600 |
$30,203
733,434
kWh
|
$6,887
-
kW-mo/yr
|
$1,484 |
$17,996
-
MMBtu
|
||
TOTAL IMPLEMENTED | $46,693 | $53,600 |
$22,329
542,220
kWh
|
$5,264
-
kW-mo/yr
|
$1,104 |
$17,996
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs