Assessment Year | 2002 |
---|---|
Principal Product | Rice |
NAICS |
n/a
|
SIC | 2044: Rice Milling |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
1,873,066
ft2
|
Annual Production | 450,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $313,877 | 6,285,800 |
kWh
|
$0.050 |
Electricity Demand | $99,225 | 17,661 |
kW-mo/yr
|
$5.62 |
Electricity Fees | $14,819 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,400 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $20,004 | $29,820 | - |
$19,235
-
kW-mo/yr
|
$769 | |
02 | 2.8112: Combine utility meters | $1,200 | - | - | - | $1,200 | |
03 | 2.7134: Use photocell controls | $504 | $130 |
$294
5,897
kWh
|
$191
-
kW-mo/yr
|
$19 | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $259 | - |
$134
2,691
kWh
|
$115
-
kW-mo/yr
|
$10 | |
05 | 2.7135: Install occupancy sensors | $137 | $82 |
$81
1,616
kWh
|
$51
-
kW-mo/yr
|
$5 | |
TOTAL RECOMMENDED | $22,104 | $30,032 |
$509
10,204
kWh
|
$19,592
-
kW-mo/yr
|
$2,003 | ||
TOTAL IMPLEMENTED | $20,400 | $29,902 |
$215
4,307
kWh
|
$19,401
-
kW-mo/yr
|
$784 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs