| Assessment Year | 2002 |
|---|---|
| Principal Product | Stairs |
| NAICS |
n/a
|
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $1 M to 5M |
| # of Employees | 25 |
| Plant Area |
41,800
ft2
|
| Annual Production | 4,500
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,602 | 337,169 |
kWh
|
$0.070 |
| Natural Gas | $22,837 | 2,140 |
MMBtu
|
$10.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,529 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $601 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $2,920 | $947 | - |
$2,920
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $981 | $630 |
$981
13,472
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $751 | $780 |
$751
10,317
kWh
|
- | |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $601 | $418 |
$601
8,253
kWh
|
- | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $276 | - |
$276
3,794
kWh
|
- | |
| TOTAL RECOMMENDED | $5,529 | $2,775 |
$2,609
35,836
kWh
|
$2,920
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $601 | $418 |
$601
8,253
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs