| Assessment Year | 2001 |
|---|---|
| Principal Product | Styrene |
| NAICS |
n/a
|
| SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
| Sales Range | $100 M to 500M |
| # of Employees | 17 |
| Plant Area |
483,000
ft2
|
| Annual Production | 400,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,126,859 | 19,202,000 |
kWh
|
$0.059 |
| Natural Gas | $12,744,950 | 2,390,267 |
MMBtu
|
$5.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,556,196 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $370,482 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $477,641 | $1,116,799 |
$976,435
16,000,000
kWh
|
$(-498,794.0)
-
MMBtu
|
|
| 02 | 2.1331: Burn a less expensive grade of fuel | $1,598,858 | $154,800 | - |
$1,598,858
-
MMBtu
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,154 | $1,200 |
$11,154
190,078
kWh
|
- | |
| 04 | 2.2511: Insulate bare equipment | $5,437 | $9,810 | - |
$5,437
-
MMBtu
|
|
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $353,891 | $50,860 | - |
$353,891
-
MMBtu
|
|
| 06 | 2.7134: Use photocell controls | $109,215 | $1,962 |
$109,215
1,861,200
kWh
|
- | |
| TOTAL RECOMMENDED | $2,556,196 | $1,335,431 |
$1,096,804
18,051,278
kWh
|
$1,459,392
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $370,482 | $61,870 |
$11,154
190,078
kWh
|
$359,328
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs