Assessment Year | 2001 |
---|---|
Principal Product | Styrene |
NAICS |
n/a
|
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $100 M to 500M |
# of Employees | 17 |
Plant Area |
483,000
ft2
|
Annual Production | 400,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,126,859 | 19,202,000 |
kWh
|
$0.059 |
Natural Gas | $12,744,950 | 2,390,267 |
MMBtu
|
$5.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,556,196 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $370,482 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $477,641 | $1,116,799 |
$976,435
16,000,000
kWh
|
$(-498,794.0)
-
MMBtu
|
|
02 | 2.1331: Burn a less expensive grade of fuel | $1,598,858 | $154,800 | - |
$1,598,858
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,154 | $1,200 |
$11,154
190,078
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $5,437 | $9,810 | - |
$5,437
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $353,891 | $50,860 | - |
$353,891
-
MMBtu
|
|
06 | 2.7134: Use photocell controls | $109,215 | $1,962 |
$109,215
1,861,200
kWh
|
- | |
TOTAL RECOMMENDED | $2,556,196 | $1,335,431 |
$1,096,804
18,051,278
kWh
|
$1,459,392
-
MMBtu
|
||
TOTAL IMPLEMENTED | $370,482 | $61,870 |
$11,154
190,078
kWh
|
$359,328
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |