| Assessment Year | 2001 |
|---|---|
| Principal Product | Offshore drilling completion equipment |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 94 |
| Plant Area |
45,600
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $193,878 | 2,506,650 |
kWh
|
$0.077 |
| Electricity Demand | $41,672 | 7,392 |
kW-mo/yr
|
$5.64 |
| Electricity Fees | $(-28,338.0) | - |
|
- |
| Natural Gas | $7,004 | 598 |
MMBtu
|
$11.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,858 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,588 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $6,070 | $8,640 | - |
$5,837
-
kW-mo/yr
|
$233 | - | - | |
| 02 | 2.7134: Use photocell controls | $6,866 | $325 |
$4,854
67,392
kWh
|
$1,748
-
kW-mo/yr
|
$264 | - | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $5,657 | $82 |
$4,450
61,776
kWh
|
$989
-
kW-mo/yr
|
$218 | - | - | |
| 04 | 2.4321: Upgrade obsolete equipment | $441 | $180 |
$424
5,887
kWh
|
- | $17 | - | - | |
| 05 | 2.8123: Pay utility bills on time | $296 | - | - | - | $296 | - | - | |
| 06 | 3.5313: Increase amount of waste recovered for resale | $18,851 | - | - | - | - | - |
$18,851
-
lb
|
|
| 07 | 3.4133: Clean fouling from water lines regularly | $9,677 | $2,200 | - | - | - |
$9,677
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $47,858 | $11,427 |
$9,728
135,055
kWh
|
$8,574
-
kW-mo/yr
|
$1,028 |
$9,677
-
Tgal
|
$18,851
-
lb
|
||
| TOTAL IMPLEMENTED | $19,588 | $180 |
$424
5,887
kWh
|
- | $313 | - |
$18,851
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs