Assessment Year | 2023 |
---|---|
Principal Product | Chicken |
NAICS | 311615: Poultry Processing |
SIC | 2015: Poultry Slaughtering and Processing |
Sales Range | $5 M to 10M |
# of Employees | 36 |
Plant Area |
15,000
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $51,025 | 412,960 |
kWh
|
$0.12 | |
Electricity Demand | $37,620 | 1,364 |
kW-mo/yr
|
$27.58 | |
Electricity Fees | $6,396 | - |
|
- | |
Natural Gas | $33,791 | 2,865 |
MMBtu
|
$11.79 | |
Waste Disposal Costs | |||||
Water Usage | $74,430 | 5,390 |
Tgal
|
$13.81 | |
TOTAL YEARLY COSTS | $203,262 | ||||
RECOMMENDED SAVINGS* | $11,219 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $9,622 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $839 | $100 |
$452
3,650
kWh
|
$387
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,597 | $3,000 |
$935
7,537
kWh
|
$662
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,298 | $8,400 |
$1,115
9,000
kWh
|
$3,183
-
kW-mo/yr
|
- | |
04 | 2.2511: Insulate bare equipment | $210 | $760 | - | - |
$210
-
MMBtu
|
|
05 | 2.7232: Replace existing hvac unit with high efficiency model | $2,200 | $9,000 |
$1,306
10,533
kWh
|
$894
-
kW-mo/yr
|
- | |
06 | 2.7233: Use properly designed and sized hvac equipment | $2,075 | $13,169 | - | - |
$2,075
-
MMBtu
|
|
TOTAL RECOMMENDED | $11,219 | $34,429 |
$3,808
30,720
kWh
|
$5,126
-
kW-mo/yr
|
$2,285
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,622 | $31,429 |
$2,873
23,183
kWh
|
$4,464
-
kW-mo/yr
|
$2,285
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs