| Assessment Year | 2022 |
|---|---|
| Principal Product | Ice |
| NAICS | 312113: Ice Manufacturing |
| SIC | 2097: Manufactured Ice |
| Sales Range | $10 M to 50M |
| # of Employees | 25 |
| Plant Area |
120,000
ft2
|
| Annual Production | 20,000,000
units
|
| Production Hrs. Annual | 6,212
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $251,075 | 4,649,541 |
kWh
|
$0.054 |
| Electricity Demand | $47,773 | 11,484 |
kW-mo/yr
|
$4.16 |
| Electricity Fees | $61,403 | - |
|
- |
| TOTAL YEARLY COSTS | $360,251 | |||
| RECOMMENDED SAVINGS* | $19,887 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,247 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,006 | $35 |
$848
15,701
kWh
|
$158
-
kW-mo/yr
|
|
| 02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $9,676 | $23,000 |
$8,981
166,317
kWh
|
$695
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,247 | $4,450 |
$1,076
19,920
kWh
|
$171
-
kW-mo/yr
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $7,958 | $50,000 |
$7,197
133,282
kWh
|
$761
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $19,887 | $77,485 |
$18,102
335,220
kWh
|
$1,785
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $1,247 | $4,450 |
$1,076
19,920
kWh
|
$171
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs