Assessment Year 2020
Principal Product Printed objects
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 185
Plant Area 155,000
ft2
Annual Production 40,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $231,618 3,739,200
kWh
Electricity Demand $21,403 8,404
kW-mo/yr
Electricity Fees $8,305 -
Natural Gas $18,353 2,599
MMBtu
TOTAL YEARLY COSTS $279,679
RECOMMENDED SAVINGS* $10,543 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,065 $40 $986
15,895
kWh
$79
-
kW-mo/yr
-
02 2.7261: Install timers and/or thermostats $2,183 $360 $955
15,401
kWh
- $1,228
-
MMBtu
03 2.6212: Turn off equipment during breaks, reduce operating time $1,226 $270 $475
7,658
kWh
$751
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,360 $1,375 $1,258
20,801
kWh
$102
-
kW-mo/yr
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $122 $360 $122
1,971
kWh
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $4,587 $20,636 $4,217
68,028
kWh
$370
-
kW-mo/yr
-
TOTAL RECOMMENDED $10,543 $23,041 $8,013
129,754
kWh
$1,302
-
kW-mo/yr
$1,228
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs