Assessment Year 2019
Principal Product Hydraulic Turbines
NAICS 333511: Industrial Mold Manufacturing
SIC 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units
Sales Range $1
M
to 5
M
# of Employees 330
Plant Area 400,000
ft2
Annual Production 40
units
Production Hrs. Annual 6,240
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $370,636 7,338,110
kWh
Electricity Demand $70,165 20,450
kW-mo/yr
Electricity Fees $52,210 -
Natural Gas $173,129 26,230
MMBtu
TOTAL YEARLY COSTS $666,140
RECOMMENDED SAVINGS* $53,352 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,351

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $339 $310 $106
2,150
kWh
$233
-
kW-mo/yr
-
02 2.2437: Recover waste heat from equipment $9,431 $9,000 - - $9,431
-
MMBtu
03 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $20,437 $22,500 $(-447.0)
(-8,728)
kWh
- $20,884
-
MMBtu
04 2.4231: Reduce the pressure of compressed air to the minimum required $3,667 $6,000 $3,372
65,170
kWh
$295
-
kW-mo/yr
-
05 2.4323: Use optimum size and capacity equipment $1,469 $3,500 $1,469
28,799
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $34 $105 $34
657
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $3,351 $15,513 $2,867
56,223
kWh
$484
-
kW-mo/yr
-
08 2.7232: Replace existing hvac unit with high efficiency model $14,624 $75,000 $11,619
227,816
kWh
$3,005
-
kW-mo/yr
-
TOTAL RECOMMENDED $53,352 $131,928 $19,020
372,087
kWh
$4,017
-
kW-mo/yr
$30,315
-
MMBtu
TOTAL IMPLEMENTED $3,351 $15,513 $2,867
56,223
kWh
$484
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs