Assessment Year 2019
Principal Product Flexible Packaging
NAICS 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing
SIC 2891: Adhesives and Sealants
Sales Range $100
M
to 500
M
# of Employees 123
Plant Area 250,000
ft2
Annual Production 1,000,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,133,586 20,193,600
kWh
Electricity Demand $101,940 40,026
kW-mo/yr
Electricity Fees $28,968 -
Natural Gas $523,324 122,764
MMBtu
TOTAL YEARLY COSTS $1,787,818
RECOMMENDED SAVINGS* $352,427 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.8123: Pay utility bills on time $4,000 - - - $4,000
02 3.1194: Use automatic flow control $20,000 $6,500 - - $20,000
03 2.2614: Use cooling tower or economizer to replace chiller cooling $25,833 $35,000 $24,602
439,316
kWh
$1,231
-
kW-mo/yr
-
04 2.4226: Use / purchase optimum sized compressor $10,332 $25,000 $8,792
156,994
kWh
$1,540
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $23,769 $115,000 $21,627
386,190
kWh
$2,142
-
kW-mo/yr
-
06 2.7232: Replace existing hvac unit with high efficiency model $268,493 $1,534,575 $252,688
4,512,293
kWh
$15,805
-
kW-mo/yr
-
TOTAL RECOMMENDED $352,427 $1,716,075 $307,709
5,494,793
kWh
$20,718
-
kW-mo/yr
$24,000
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs