ITAC Assessment: LE0463
ITAC logo
ITAC Assessment: LE0463
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Specialty Chemicals
NAICS 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing
SIC 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 71
Plant Area 50,000
ft2
Annual Production 1,540,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $251,012 3,857,525
kWh
Electricity Demand $64,123 11,284
kW-mo/yr
Electricity Fees $11,638 -
Natural Gas $135,316 16,700
MMBtu
TOTAL YEARLY COSTS $462,089
RECOMMENDED SAVINGS* $134,847 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,655

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,239 $70 $1,125
17,321
kWh
$114
-
kW-mo/yr
-
02 2.7232: Replace existing hvac unit with high efficiency model $53,879 $30,500 $31,686
487,472
kWh
$2,948
-
kW-mo/yr
$19,245
-
MMBtu
03 2.4322: Use or replace with energy efficient substitutes $6,825 $7,525 $4,780
73,536
kWh
$2,045
-
kW-mo/yr
-
04 2.6212: Turn off equipment during breaks, reduce operating time $19,392 $30,000 $17,887
275,184
kWh
$1,505
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $22,792 $85,052 $19,924
306,519
kWh
$2,868
-
kW-mo/yr
-
06 2.1224: Replace boiler $9,096 $35,000 - - $9,096
-
MMBtu
07 2.7232: Replace existing hvac unit with high efficiency model $21,624 $93,750 $19,307
297,024
kWh
$2,317
-
kW-mo/yr
-
TOTAL RECOMMENDED $134,847 $281,897 $94,709
1,457,056
kWh
$11,797
-
kW-mo/yr
$28,341
-
MMBtu
TOTAL IMPLEMENTED $45,655 $178,872 $40,356
620,864
kWh
$5,299
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs