Assessment Year | 2018 |
---|---|
Principal Product | Plastic |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
197,000
ft2
|
Annual Production | 90,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,295,221 | 43,572,000 |
kWh
|
$0.053 |
Electricity Demand | $140,201 | 62,011 |
kW-mo/yr
|
$2.26 |
Electricity Fees | $163,660 | - |
|
- |
Natural Gas | $429,225 | 94,764 |
MMBtu
|
$4.53 |
TOTAL YEARLY COSTS | $3,028,307 | |||
RECOMMENDED SAVINGS* | $127,201 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $84,004 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $70,484 | $4,500 |
$65,627
1,238,241
kWh
|
$4,857
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,972 | $1,125 |
$3,550
66,980
kWh
|
$3,422
-
kW-mo/yr
|
- | |
03 | 2.2437: Recover waste heat from equipment | $7,248 | $4,000 | - | - |
$7,248
-
MMBtu
|
|
04 | 2.7135: Install occupancy sensors | $1,037 | $1,550 |
$1,037
19,569
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,499 | $3,938 |
$2,361
44,554
kWh
|
$138
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,507 | $11,250 |
$3,473
65,520
kWh
|
$2,034
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,514 | $19,688 |
$5,209
98,280
kWh
|
$305
-
kW-mo/yr
|
- | |
08 | 2.2622: Replace existing chiller with high efficiency model | $27,940 | $105,000 |
$26,391
497,952
kWh
|
$1,549
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $127,201 | $151,051 |
$107,648
2,031,096
kWh
|
$12,305
-
kW-mo/yr
|
$7,248
-
MMBtu
|
||
TOTAL IMPLEMENTED | $84,004 | $39,376 |
$76,670
1,446,595
kWh
|
$7,334
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs