Assessment Year | 2016 |
---|---|
Principal Product | Precision Metal / Plastic Components |
NAICS | 332710: Machine Shops |
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $10 M to 50M |
# of Employees | 18 |
Plant Area |
107,000
ft2
|
Annual Production | 9,500,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $154,165 | 1,815,352 |
kWh
|
$0.085 |
Electricity Demand | $22,785 | 5,452 |
kW-mo/yr
|
$4.18 |
Electricity Fees | $8,904 | - |
|
- |
Natural Gas | $36,634 | 3,927 |
MMBtu
|
$9.33 |
TOTAL YEARLY COSTS | $222,488 | |||
RECOMMENDED SAVINGS* | $94,649 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,774 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $21,631 | $2,000 |
$12,138
142,800
kWh
|
$853
-
kW-mo/yr
|
$8,640
-
MMBtu
|
- | |
02 | 2.7135: Install occupancy sensors | $1,594 | $218 |
$1,594
18,752
kWh
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $3,645 | $510 |
$3,645
43,234
kWh
|
- | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,358 | $415 |
$1,286
15,133
kWh
|
$72
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,151 | $1,000 |
$2,013
23,702
kWh
|
$138
-
kW-mo/yr
|
- | - | |
06 | 2.4323: Use optimum size and capacity equipment | $1,304 | $1,350 |
$1,304
15,334
kWh
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,924 | $3,037 |
$1,402
16,500
kWh
|
$1,522
-
kW-mo/yr
|
- | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $990 | $1,500 |
$890
10,467
kWh
|
$100
-
kW-mo/yr
|
- | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,319 | $3,000 |
$1,236
14,537
kWh
|
$83
-
kW-mo/yr
|
- | - | |
10 | 2.7135: Install occupancy sensors | $713 | $2,175 |
$713
8,387
kWh
|
- | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,926 | $6,250 |
$1,456
17,108
kWh
|
$234
-
kW-mo/yr
|
- | $236 | |
12 | 2.2622: Replace existing chiller with high efficiency model | $55,094 | $185,000 |
$51,608
607,152
kWh
|
$3,486
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $94,649 | $206,455 |
$79,285
933,106
kWh
|
$6,488
-
kW-mo/yr
|
$8,640
-
MMBtu
|
$236 | ||
TOTAL IMPLEMENTED | $4,774 | $5,350 |
$4,553
53,573
kWh
|
$221
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs