Assessment Year | 2014 |
---|---|
Principal Product | Steel Drum |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
122,000
ft2
|
Annual Production | 1,500,000
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $326,611 | 4,744,236 |
kWh
|
$0.069 |
Electricity Demand | $94,810 | 18,730 |
kW-mo/yr
|
$5.06 |
Electricity Fees | $143,183 | - |
|
- |
Natural Gas | $502,127 | 72,632 |
MMBtu
|
$6.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,631 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,520 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $3,075 | $660 | - | - |
$3,075
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,302 | $1,000 |
$3,214
46,582
kWh
|
$1,088
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,540 | $1,000 |
$1,150
16,677
kWh
|
$390
-
kW-mo/yr
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,662 | $1,353 |
$1,229
17,805
kWh
|
$433
-
kW-mo/yr
|
- | - | |
05 | 2.2442: Preheat combustion air with waste heat | $5,797 | $5,400 | - | - |
$5,797
-
MMBtu
|
- | |
06 | 2.2511: Insulate bare equipment | $17,652 | $17,399 | - | - |
$17,652
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,743 | $5,800 |
$1,135
16,453
kWh
|
$275
-
kW-mo/yr
|
- | $1,333 | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,860 | $36,800 |
$8,870
128,546
kWh
|
$2,990
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $48,631 | $69,412 |
$15,598
226,063
kWh
|
$5,176
-
kW-mo/yr
|
$26,524
-
MMBtu
|
$1,333 | ||
TOTAL IMPLEMENTED | $23,520 | $45,260 |
$14,369
208,258
kWh
|
$4,743
-
kW-mo/yr
|
$3,075
-
MMBtu
|
$1,333 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs