Assessment Year | 2011 |
---|---|
Principal Product | Frozen Food |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2053: Frozen Bakery Products, Except Bread |
Sales Range | $100 M to 500M |
# of Employees | 329 |
Plant Area |
233,000
ft2
|
Annual Production | 64,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,061,733 | 18,520,951 |
kWh
|
$0.057 |
Electricity Demand | $516,916 | 35,132 |
kW-mo/yr
|
$14.71 |
Natural Gas | $323,347 | 59,394 |
MMBtu
|
$5.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $541,066 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,698 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $404,827 | $2,200,000 |
$957,600
16,800,000
kWh
|
$353,040
-
kW-mo/yr
|
$(-905,813.0)
-
MMBtu
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $48,359 | $25,500 |
$32,319
567,003
kWh
|
$16,040
-
kW-mo/yr
|
- | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $25,842 | $2,500 | - |
$25,842
-
kW-mo/yr
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $22,464 | $250 |
$16,097
282,408
kWh
|
- |
$6,367
-
MMBtu
|
- | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $18,864 | $50,000 |
$5,332
93,542
kWh
|
$2,265
-
kW-mo/yr
|
$9,267
-
MMBtu
|
$2,000 | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,689 | $40 |
$5,675
99,572
kWh
|
$2,014
-
kW-mo/yr
|
- | - | |
07 | 2.2442: Preheat combustion air with waste heat | $6,281 | $20,000 | - | - |
$6,281
-
MMBtu
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,370 | $2,000 |
$3,230
56,631
kWh
|
$2,140
-
kW-mo/yr
|
- | - | |
09 | 2.2136: Install / repair insulation on steam lines | $1,370 | $249 | - | - |
$1,370
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $541,066 | $2,300,539 |
$1,020,253
17,899,156
kWh
|
$401,341
-
kW-mo/yr
|
$(-882,528.0)
-
MMBtu
|
$2,000 | ||
TOTAL IMPLEMENTED | $42,698 | $50,499 |
$21,429
375,950
kWh
|
$2,265
-
kW-mo/yr
|
$17,004
-
MMBtu
|
$2,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs