Assessment Year | 2007 |
---|---|
Principal Product | Fluid Power Products |
NAICS | 333996: Fluid Power Pump and Motor Manufacturing |
SIC | 3594: Fluid Power Pumps and Motors |
Sales Range | $50 M to 100M |
# of Employees | 123 |
Plant Area |
75,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $103,074 | 1,586,200 |
kWh
|
$0.065 |
Electricity Demand | $38,007 | 4,264 |
kW-mo/yr
|
$8.91 |
Natural Gas | $22,727 | 1,681 |
MMBtu
|
$13.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $120,968 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $67,607 | $74,000 |
$16,848
259,200
kWh
|
$4,491
-
kW-mo/yr
|
$46,268
-
MMBtu
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $11,871 | $60 |
$9,395
144,531
kWh
|
$2,476
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,263 | $1,000 |
$4,957
76,259
kWh
|
$1,306
-
kW-mo/yr
|
- | - | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,657 | $8,000 | - |
$4,657
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $3,696 | $1,350 |
$3,696
56,861
kWh
|
- | - | - | |
06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $2,799 | $2,500 | - | - | - |
$2,799
-
lb
|
|
07 | 3.4151: Minimize water usage | $1,524 | $1,000 |
$134
2,958
kWh
|
$1,390
-
kW-mo/yr
|
- | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $816 | $200 |
$614
9,433
kWh
|
$202
-
kW-mo/yr
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $234 | $500 |
$161
2,471
kWh
|
$73
-
kW-mo/yr
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,501 | $54,052 |
$17,016
261,784
kWh
|
$4,485
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $120,968 | $142,662 |
$52,821
813,497
kWh
|
$19,080
-
kW-mo/yr
|
$46,268
-
MMBtu
|
$2,799
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs