Assessment Year | 2006 |
---|---|
Principal Product | newspaper advertising inserts |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $50 M to 100M |
# of Employees | 210 |
Plant Area |
149,717
ft2
|
Annual Production | 1,889,712,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $897,480 | 20,679,155 |
kWh
|
$0.043 |
Electricity Demand | $378,026 | 39,584 |
kW-mo/yr
|
$9.55 |
Natural Gas | $1,305,019 | 119,292 |
MMBtu
|
$10.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $143,142 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $135,437 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $19,350 | $1,000 |
$14,327
333,172
kWh
|
$5,023
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,690 | $1,000 |
$14,321
333,051
kWh
|
$4,369
-
kW-mo/yr
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $15,950 | $1,024 |
$11,108
258,337
kWh
|
$4,842
-
kW-mo/yr
|
|
04 | 2.4112: Install soft-start to eliminate nuisance trips | $13,305 | $42,000 | - |
$13,305
-
kW-mo/yr
|
|
05 | 2.7221: Lower temperature during the winter season and vice-versa | $7,705 | $50 |
$4,784
111,289
kWh
|
$2,921
-
kW-mo/yr
|
|
06 | 2.7272: Install heat pipes / raise cooling setpoint | $2,252 | $50 |
$1,725
40,126
kWh
|
$527
-
kW-mo/yr
|
|
07 | 2.7135: Install occupancy sensors | $4,751 | $450 |
$4,751
110,475
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $61,139 | $68,713 |
$46,846
1,089,484
kWh
|
$14,293
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $143,142 | $114,287 |
$97,862
2,275,934
kWh
|
$45,280
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $135,437 | $114,237 |
$93,078
2,164,645
kWh
|
$42,359
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs