Assessment Year | 2006 |
---|---|
Principal Product | Semiconductor equipment material |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $50 M to 100M |
# of Employees | 100 |
Plant Area |
75,600
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $948,839 | 11,170,776 |
kWh
|
$0.085 |
Electricity Demand | $137,133 | 19,878 |
kW-mo/yr
|
$6.90 |
Electricity Fees | $21,102 | - |
|
- |
Natural Gas | $297,439 | 29,553 |
MMBtu
|
$10.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $300,336 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $256,667 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $190,924 | $500,000 |
$109,573
1,289,098
kWh
|
$10,175
-
kW-mo/yr
|
- | - | $30,000 | $41,176 | |
02 | 2.2113: Repair or replace steam traps | $46,545 | $3,000 | - | - | - |
$46,545
-
MMBtu
|
- | - | |
03 | 2.3212: Optimize plant power factor | $21,102 | $32,700 | - | - | $21,102 | - | - | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $22,567 | $1,250 | - | - | - |
$22,567
-
MMBtu
|
- | - | |
05 | 2.7496: Install partitions to reduce size of conditioned space | $10,090 | $6,000 | - | - | - |
$10,090
-
MMBtu
|
- | - | |
06 | 2.7135: Install occupancy sensors | $5,320 | $1,500 |
$5,320
62,593
kWh
|
- | - | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,195 | $3,490 |
$2,995
35,251
kWh
|
$200
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $593 | $60 |
$524
5,993
kWh
|
$69
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $300,336 | $548,000 |
$118,412
1,392,935
kWh
|
$10,444
-
kW-mo/yr
|
$21,102 |
$79,202
-
MMBtu
|
$30,000 | $41,176 | ||
TOTAL IMPLEMENTED | $256,667 | $514,050 |
$118,412
1,392,935
kWh
|
$10,444
-
kW-mo/yr
|
- |
$56,635
-
MMBtu
|
$30,000 | $41,176 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs