Assessment Year | 2004 |
---|---|
Principal Product | Remanufactured Engines,Transmissions, and Carriers |
NAICS | 333618: Other Engine Equipment Manufacturing |
SIC | 3519: Internal Combustion Engines, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 152 |
Plant Area |
120,000
ft2
|
Annual Production | 172,450
pieces
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,080 | 2,676,000 |
kWh
|
$0.056 |
Electricity Demand | $58,928 | 8,491 |
kW-mo/yr
|
$6.94 |
Natural Gas | $29,471 | 2,549 |
MMBtu
|
$11.56 |
Fuel Oil #1 | $41,891 | 5,603 |
MMBtu
|
$7.48 |
Fuel Oil #2 | $41,891 | 5,603 |
MMBtu
|
$7.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $100,370 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $78,664 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.652: Replace existing equipment with more suitable substitutes | $65,403 | $20,000 | - | - | - | - |
$41,891
-
MMBtu
|
$23,512 | |
02 | 2.8114: Change rate schedules or other changes in utility service | $17,844 | $50,000 | - | - | $17,844 | - | - | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,450 | $2,500 | - |
$2,450
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,412 | $750 | - | - | - |
$1,412
-
MMBtu
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,074 | $218 |
$857
15,303
kWh
|
$217
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,187 | $33,512 |
$9,541
170,368
kWh
|
$2,646
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $100,370 | $106,980 |
$10,398
185,671
kWh
|
$5,313
-
kW-mo/yr
|
$17,844 |
$1,412
-
MMBtu
|
$41,891
-
MMBtu
|
$23,512 | ||
TOTAL IMPLEMENTED | $78,664 | $53,730 |
$10,398
185,671
kWh
|
$2,863
-
kW-mo/yr
|
- | - |
$41,891
-
MMBtu
|
$23,512 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs