Assessment Year 2025
Principal Product Seals and Gaskets
NAICS 339999: All Other Miscellaneous Manufacturing
SIC 3053: Gaskets, Packing, and Sealing Devices
Sales Range $10
M
to 50
M
# of Employees 174
Plant Area 67,000
ft2
Annual Production 450
units
Production Hrs. Annual 5,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $468,760 2,688,825
kWh
Electricity Demand $384,192 6,307
kW-mo/yr
TOTAL YEARLY COSTS $852,952
RECOMMENDED SAVINGS* $746,877 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Primary Product Savings
01 2.9114: Use solar heat to make electricty $418,912 $524,659 $168,897
969,000
kWh
$250,016
-
kW-mo/yr
-
02 2.3141: Use battery storage for demand control $260,930 $10,784 $(-9,850.6)
(-56,515)
kWh
$270,781
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $41,190 $8,318 $23,261
133,452
kWh
$17,929
-
kW-mo/yr
-
04 2.1121: Use insulation in furnaces to facilitate heating / cooling $2,121 $299 $1,307
7,500
kWh
$813
-
kW-mo/yr
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,877 $3,727 $1,919
11,010
kWh
$958
-
kW-mo/yr
-
06 4.212: Adopt in-house material generation $17,049 $46,406 $(-4,551.0)
(-26,110)
kWh
- $21,600
07 2.4231: Reduce the pressure of compressed air to the minimum required $3,797 - $3,797
21,785
kWh
- -
TOTAL RECOMMENDED $746,877 $594,193 $184,779
1,060,122
kWh
$540,497
-
kW-mo/yr
$21,600
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs