Assessment Year | 2004 |
---|---|
Principal Product | Heating Appliances |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
117,000
ft2
|
Annual Production | 12,000
pieces
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,066 | 1,708,500 |
kWh
|
$0.048 |
Electricity Demand | $35,436 | 5,106 |
kW-mo/yr
|
$6.94 |
Natural Gas | $13,856 | 1,076 |
MMBtu
|
$12.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,443 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Coal Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $10,362 | $942 | - | - |
$10,362
-
MMBtu
|
- | - | |
02 | 3.5316: Contract a wood pallet recycling company | $2,781 | - | - | - | - | - |
$2,781
-
lb
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $1,423 | $89 |
$999
20,808
kWh
|
$424
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,185 | - |
$1,185
24,695
kWh
|
- | - | - | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $960 | $750 | - | - | - |
$960
-
MMBtu
|
- | |
06 | 2.4314: Use synthetic lubricant | $573 | $500 |
$185
3,859
kWh
|
$388
-
kW-mo/yr
|
- | - | - | |
07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $532 | - | - |
$532
-
kW-mo/yr
|
- | - | - | |
08 | 3.5217: Reuse / recycle/ sell paper products | $451 | - | - | - | - | - |
$451
-
lb
|
|
09 | 2.2511: Insulate bare equipment | $218 | $279 | - | - | - |
$218
-
MMBtu
|
- | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $215 | - |
$170
3,539
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $18,700 | $2,560 |
$2,539
52,901
kWh
|
$1,389
-
kW-mo/yr
|
$10,362
-
MMBtu
|
$1,178
-
MMBtu
|
$3,232
-
lb
|
||
TOTAL IMPLEMENTED | $5,443 | $589 |
$1,354
28,206
kWh
|
$857
-
kW-mo/yr
|
- | - |
$3,232
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Coal Savings | Solid Waste (non-haz) Savings |