| Assessment Year | 2004 |
|---|---|
| Principal Product | Heating Appliances |
| NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
| SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
| Sales Range | $10 M to 50M |
| # of Employees | 135 |
| Plant Area |
117,000
ft2
|
| Annual Production | 12,000
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,066 | 1,708,500 |
kWh
|
$0.048 |
| Electricity Demand | $35,436 | 5,106 |
kW-mo/yr
|
$6.94 |
| Natural Gas | $13,856 | 1,076 |
MMBtu
|
$12.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,443 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Coal Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $10,362 | $942 | - | - |
$10,362
-
MMBtu
|
- | - | |
| 02 | 3.5316: Contract a wood pallet recycling company | $2,781 | - | - | - | - | - |
$2,781
-
lb
|
|
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $1,423 | $89 |
$999
20,808
kWh
|
$424
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,185 | - |
$1,185
24,695
kWh
|
- | - | - | - | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $960 | $750 | - | - | - |
$960
-
MMBtu
|
- | |
| 06 | 2.4314: Use synthetic lubricant | $573 | $500 |
$185
3,859
kWh
|
$388
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $532 | - | - |
$532
-
kW-mo/yr
|
- | - | - | |
| 08 | 3.5217: Reuse / recycle/ sell paper products | $451 | - | - | - | - | - |
$451
-
lb
|
|
| 09 | 2.2511: Insulate bare equipment | $218 | $279 | - | - | - |
$218
-
MMBtu
|
- | |
| 10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $215 | - |
$170
3,539
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $18,700 | $2,560 |
$2,539
52,901
kWh
|
$1,389
-
kW-mo/yr
|
$10,362
-
MMBtu
|
$1,178
-
MMBtu
|
$3,232
-
lb
|
||
| TOTAL IMPLEMENTED | $5,443 | $589 |
$1,354
28,206
kWh
|
$857
-
kW-mo/yr
|
- | - |
$3,232
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Coal Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs