| Assessment Year | 2003 |
|---|---|
| Principal Product | Insulation Facings (Paper Laminate) |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | n/a |
| # of Employees | 103 |
| Plant Area |
155,000
ft2
|
| Annual Production | 1,000,000
thousand feet
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $376,987 | 5,130,800 |
kWh
|
$0.073 |
| Electricity Demand | $146,189 | 15,496 |
kW-mo/yr
|
$9.43 |
| Natural Gas | $126,243 | 14,518 |
MMBtu
|
$8.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $215,254 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,966 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $210,423 | $300,000 |
$168,780
2,296,320
kWh
|
$41,643
-
kW-mo/yr
|
- | |
| 02 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $2,647 | $7,000 |
$2,647
36,016
kWh
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $952 | - |
$952
12,948
kWh
|
- | - | |
| 04 | 2.2625: Chill water to the highest temperature possible | $367 | - |
$367
4,992
kWh
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $440 | $560 | - | - |
$440
-
MMBtu
|
|
| 06 | 2.7135: Install occupancy sensors | $425 | $825 |
$425
5,781
kWh
|
- | - | |
| TOTAL RECOMMENDED | $215,254 | $308,385 |
$173,171
2,356,057
kWh
|
$41,643
-
kW-mo/yr
|
$440
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,966 | $7,000 |
$3,966
53,956
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs