Assessment Year | 2003 |
---|---|
Principal Product | Chewing Gum Base |
NAICS | 311340: Nonchocolate Confectionery Manufacturing |
SIC | 2067: Chewing Gum |
Sales Range | $50 M to 100M |
# of Employees | 202 |
Plant Area |
550,000
ft2
|
Annual Production | 80,000,000
lb
|
Production Hrs. Annual | 6,912
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $662,604 | 9,903,275 |
kWh
|
$0.067 |
Electricity Demand | $171,644 | 21,982 |
kW-mo/yr
|
$7.81 |
Natural Gas | $734,138 | 117,435 |
MMBtu
|
$6.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $89,577 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $62,558 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4323: Use optimum size and capacity equipment | $3,947 | $3,000 |
$3,947
59,003
kWh
|
- | - | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $13,069 | - |
$10,431
155,928
kWh
|
$2,638
-
kW-mo/yr
|
- | - | - | |
03 | 2.2515: Use optimum thickness insulation | $51,426 | $6,735 | - | - | - |
$51,426
-
MMBtu
|
- | |
04 | 2.4314: Use synthetic lubricant | $7,733 | $1,000 |
$6,170
92,234
kWh
|
$1,563
-
kW-mo/yr
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $1,064 | $4,425 |
$1,064
15,904
kWh
|
- | - | - | - | |
06 | 2.3132: Recharge batteries on during off-peak demand periods | $1,947 | - | - | - | $1,947 | - | - | |
07 | 2.3134: Shift from daytime to nighttime operation | $4,270 | - | - | - | - | - | $4,270 | |
08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,121 | $1,000 | - | - | - |
$6,121
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $89,577 | $16,160 |
$21,612
323,069
kWh
|
$4,201
-
kW-mo/yr
|
$1,947 |
$57,547
-
MMBtu
|
$4,270 | ||
TOTAL IMPLEMENTED | $62,558 | $15,160 |
$5,011
74,907
kWh
|
- | - |
$57,547
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs