Assessment Year | 2001 |
---|---|
Principal Product | Stainless Steel Rods, Bars |
NAICS |
n/a
|
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
100,000
ft2
|
Annual Production | 63,319
lb
|
Production Hrs. Annual | 8,520
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $398,235 | 6,351,300 |
kWh
|
$0.063 |
Electricity Demand | $77,807 | 13,054 |
kW-mo/yr
|
$5.96 |
Natural Gas | $73,032 | 6,116 |
MMBtu
|
$11.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,331 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $2,814 | $2,450 |
$2,454
48,594
kWh
|
$360
-
kW-mo/yr
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $11,672 | $2,500 | - |
$11,672
-
kW-mo/yr
|
- | |
03 | 2.1331: Burn a less expensive grade of fuel | $26,023 | $54,800 | - | - |
$26,023
-
MMBtu
|
|
04 | 2.6211: Conserve energy by efficient use of vending machines | $6,091 | - |
$6,091
120,613
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $4,731 | $19,320 |
$4,093
81,047
kWh
|
$638
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $51,331 | $79,070 |
$12,638
250,254
kWh
|
$12,670
-
kW-mo/yr
|
$26,023
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs