Assessment Year | 2001 |
---|---|
Principal Product | Cement and Mining Equiment |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
170,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $245,670 | 3,411,000 |
kWh
|
$0.072 |
Electricity Demand | $47,805 | 683 |
kW-mo/yr
|
$69.99 |
Fuel Oil #4 | $182,260 | 30,630 |
MMBtu
|
$5.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,729 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #4 Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,166 | $2,500 | - |
$7,166
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,785 | - |
$2,152
41,397
kWh
|
$633
-
kW-mo/yr
|
- | |
03 | 2.4312: Improve lubrication practices | $2,615 | $400 |
$2,615
50,282
kWh
|
- | - | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $11,513 | $25,360 | - | - |
$11,513
-
MMBtu
|
|
05 | 2.2111: Install steam trap | $1,315 | $1,600 | - | - |
$1,315
-
MMBtu
|
|
06 | 2.2514: Cover open tanks | $5,335 | $1,700 | - | - |
$5,335
-
MMBtu
|
|
TOTAL RECOMMENDED | $30,729 | $31,560 |
$4,767
91,679
kWh
|
$7,799
-
kW-mo/yr
|
$18,163
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||