Assessment Year | 2000 |
---|---|
Principal Product | conveyors |
NAICS |
n/a
|
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
39,200
ft2
|
Annual Production | 83,000
units
|
Production Hrs. Annual | 2,890
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $18,967 | 333,529 |
kWh
|
$0.057 |
Electricity Demand | $6,688 | 1,196 |
kW-mo/yr
|
$5.59 |
Natural Gas | $7,023 | 1,100 |
MMBtu
|
$6.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,580 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,310 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $1,640 | $6,670 | - | - | - |
$1,640
-
MMBtu
|
- | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $630 | - | - | - | - |
$630
-
MMBtu
|
- | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $680 | $200 | - | - | $680 | - | - | - | |
04 | 2.7122: Disconnect ballasts | $310 | $120 |
$210
4,103
kWh
|
$100
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $310 | $30 |
$90
1,758
kWh
|
$220
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.4151: Minimize water usage | $340 | $800 | - | - | - | - |
$340
-
Tgal
|
- | |
07 | 2.8114: Change rate schedules or other changes in utility service | $4,400 | - | - | - | - | - | - | $4,400 | |
08 | 4.111: Add equipment/ operators to reduce production bottleneck | $270 | $540 | - | - | - | - | - | $270 | |
TOTAL RECOMMENDED | $8,580 | $8,360 |
$300
5,861
kWh
|
$320
-
kW-mo/yr
|
$680 |
$2,270
-
MMBtu
|
$340
-
Tgal
|
$4,670 | ||
TOTAL IMPLEMENTED | $1,310 | $200 | - | - | $680 |
$630
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs