Assessment Year | 1999 |
---|---|
Principal Product | vinyl siding |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
180,000
ft2
|
Annual Production | 80,000,000
lb
|
Production Hrs. Annual | 8,280
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $413,833 | 16,307,738 |
kWh
|
$0.025 |
Electricity Demand | $268,139 | 29,771 |
kW-mo/yr
|
$9.01 |
Natural Gas | $32,275 | 8,015 |
MMBtu
|
$4.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $151,500 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,650 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $16,650 | $200 | - | - | - | $16,650 | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $7,250 | $2,640 |
$4,420
197,538
kWh
|
$2,830
-
kW-mo/yr
|
- | - | - | |
03 | 2.2612: Use cooling tower water instead of refrigeration | $1,870 | $1,250 |
$1,870
83,529
kWh
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $530 | $900 |
$90
4,103
kWh
|
$40
-
kW-mo/yr
|
$400 | - | - | |
05 | 4.441: Install automatic packing equipment | $125,200 | $140,000 |
$(-2,770.0)
(-123,681)
kWh
|
$(-1,330.0)
-
kW-mo/yr
|
$69,970 | - | $59,330 | |
TOTAL RECOMMENDED | $151,500 | $144,990 |
$3,610
161,489
kWh
|
$1,540
-
kW-mo/yr
|
$70,370 | $16,650 | $59,330 | ||
TOTAL IMPLEMENTED | $9,650 | $4,790 |
$6,380
285,170
kWh
|
$2,870
-
kW-mo/yr
|
$400 | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs