| Assessment Year | 1999 |
|---|---|
| Principal Product | fuel & air filters |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 170 |
| Plant Area |
162,500
ft2
|
| Annual Production | 7,000,000
pieces
|
| Production Hrs. Annual | 3,680
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $163,321 | 4,060,961 |
kWh
|
$0.040 |
| Electricity Demand | $56,713 | 10,849 |
kW-mo/yr
|
$5.23 |
| Natural Gas | $80,380 | 25,000 |
MMBtu
|
$3.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $58,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,050 | $10,000 |
$1,360
42,497
kWh
|
$2,600
-
kW-mo/yr
|
$(-910.0)
-
MMBtu
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,600 | $810 |
$910
28,136
kWh
|
$690
-
kW-mo/yr
|
- | - | |
| 03 | 2.6218: Turn off equipment when not in use | $1,000 | - |
$620
19,343
kWh
|
$380
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $700 | $1,050 |
$150
4,689
kWh
|
$50
-
kW-mo/yr
|
- | $500 | |
| 05 | 4.441: Install automatic packing equipment | $52,280 | $151,000 |
$(-190.0)
(-5,862)
kWh
|
$(-150.0)
-
kW-mo/yr
|
- | $52,620 | |
| TOTAL RECOMMENDED | $58,630 | $162,860 |
$2,850
88,803
kWh
|
$3,570
-
kW-mo/yr
|
$(-910.0)
-
MMBtu
|
$53,120 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs