Assessment Year | 1997 |
---|---|
Principal Product | valves and switches |
NAICS |
n/a
|
SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
Sales Range | $5 M to 10M |
# of Employees | 105 |
Plant Area |
49,000
ft2
|
Annual Production | 120,000
pieces
|
Production Hrs. Annual | 3,750
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $44,394 | 686,108 |
kWh
|
$0.065 |
Electricity Demand | $9,624 | 3,300 |
kW-mo/yr
|
$2.92 |
Natural Gas | $2,412 | 374 |
MMBtu
|
$6.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $134,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,650 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,310 | $190 |
$1,140
17,878
kWh
|
$170
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $560 | $660 |
$230
3,517
kWh
|
$20
-
kW-mo/yr
|
- | $310 | - | - | |
03 | 2.2511: Insulate bare equipment | $470 | $300 |
$470
7,327
kWh
|
- | - | - | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $230 | $40 |
$200
3,224
kWh
|
$30
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.4111: Use closed cycle process to minimize waste water production | $2,170 | $5,260 | - | - |
$590
-
Tgal
|
- |
$1,580
-
Tgal
|
- | |
06 | 3.4115: Recover and reuse cooling water | $1,080 | $1,180 | - | - |
$460
-
Tgal
|
- |
$620
-
Tgal
|
- | |
07 | 3.4155: Meter waste water | $230 | $100 | - | - |
$230
-
Tgal
|
- | - | - | |
08 | 4.652: Replace existing equipment with more suitable substitutes | $128,310 | $186,000 | - | - | - | - | - | $128,310 | |
TOTAL RECOMMENDED | $134,360 | $193,730 |
$2,040
31,946
kWh
|
$220
-
kW-mo/yr
|
$1,280
-
Tgal
|
$310 |
$2,200
-
Tgal
|
$128,310 | ||
TOTAL IMPLEMENTED | $3,650 | $2,430 |
$1,840
28,722
kWh
|
$190
-
kW-mo/yr
|
$690
-
Tgal
|
$310 |
$620
-
Tgal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs