| Assessment Year | 1997 |
|---|---|
| Principal Product | industrial starch polymers |
| NAICS |
n/a
|
| SIC | 3505: |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
41,270
ft2
|
| Annual Production | 32,000,000
lb
|
| Production Hrs. Annual | 8,640
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $133,221 | 5,874,560 |
kWh
|
$0.023 |
| Electricity Demand | $56,170 | 12,408 |
kW-mo/yr
|
$4.53 |
| Natural Gas | $240,552 | 98,926 |
MMBtu
|
$2.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $56,380 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,020 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Primary Raw Material Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $9,050 | $26,400 | - | - |
$9,050
-
MMBtu
|
- | - | - | - | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $7,770 | $14,200 | - | - |
$7,770
-
MMBtu
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $6,370 | $24,290 |
$4,920
216,295
kWh
|
$1,450
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $5,410 | $640 | - | - |
$5,410
-
MMBtu
|
- | - | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,270 | $1,350 |
$950
41,911
kWh
|
$320
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 2.7135: Install occupancy sensors | $320 | $400 |
$320
14,068
kWh
|
- | - | - | - | - | - | |
| 07 | 3.4116: Meter recycled water (to reduce sewer charges) | $7,660 | - | - | - | - |
$7,660
-
Tgal
|
- | - | - | |
| 08 | 3.8132: Use less toxic and volatile solvent substitutes | $310 | $1,050 | - | - | - | - |
$600
-
gal
|
$(-290.0) | - | |
| 09 | 4.611: Begin a practice of predictive / preventative maintenance | $18,220 | $4,200 | - | - | - | - | - | - | $18,220 | |
| TOTAL RECOMMENDED | $56,380 | $72,530 |
$6,190
272,274
kWh
|
$1,770
-
kW-mo/yr
|
$22,230
-
MMBtu
|
$7,660
-
Tgal
|
$600
-
gal
|
$(-290.0) | $18,220 | ||
| TOTAL IMPLEMENTED | $40,020 | $42,690 |
$4,920
216,295
kWh
|
$1,450
-
kW-mo/yr
|
$7,770
-
MMBtu
|
$7,660
-
Tgal
|
- | - | $18,220 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Primary Raw Material Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs