Assessment Year | 1994 |
---|---|
Principal Product | Web Presses |
NAICS |
n/a
|
SIC | 3555: Printing Trades Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 440 |
Plant Area |
306,000
ft2
|
Annual Production | 156
pieces
|
Production Hrs. Annual | 6,448
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $403,388 | 8,720,985 |
kWh
|
$0.046 |
Natural Gas | $40,844 | 14,405 |
MMBtu
|
$2.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,959 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,300 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,968 | $75,345 |
$21,968
322,685
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,581 | $1,123 |
$1,581
20,516
kWh
|
- | |
03 | 2.7132: Install timers on light switches in little used areas | $1,424 | $150 |
$1,424
30,774
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $312 | $500 |
$312
6,741
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $360 | $540 |
$360
5,862
kWh
|
- | |
06 | 2.4314: Use synthetic lubricant | $8,433 | $30,600 |
$8,433
128,370
kWh
|
- | |
07 | 2.2437: Recover waste heat from equipment | $4,061 | $8,050 | - |
$4,061
-
MMBtu
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,197 | $575 |
$2,197
47,479
kWh
|
- | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,993 | $225 |
$1,993
43,083
kWh
|
- | |
10 | 2.2514: Cover open tanks | $630 | $1,056 | - |
$630
-
MMBtu
|
|
TOTAL RECOMMENDED | $42,959 | $118,164 |
$38,268
605,510
kWh
|
$4,691
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,300 | $33,713 |
$16,300
282,825
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |