Assessment Year 1993
Principal Product Digger Derricks, Aerial
NAICS
n/a
SIC 3531: Construction Machinery and Equipment
Sales Range $50
M
to 100
M
# of Employees 450
Plant Area 350,000
ft2
Annual Production 1,250
pieces
Production Hrs. Annual 4,320
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $277,715 5,441,677
kWh
Natural Gas $70,388 26,198
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $2,745 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,745

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4133: Use most efficient type of electric motors $1,945 $3,615 $1,945
38,101
kWh
-
02 2.7111: Reduce illumination to minimum necessary levels $800 $4,524 - $800
-
MMBtu
TOTAL RECOMMENDED $2,745 $8,139 $1,945
38,101
kWh
$800
-
MMBtu
TOTAL IMPLEMENTED $2,745 $8,139 $1,945
38,101
kWh
$800
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs