Assessment Year | 1990 |
---|---|
Principal Product | PVC PIPE & VINYL SIDING |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $50 M to 100M |
# of Employees | 175 |
Plant Area |
n/a
|
Annual Production | 69,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $744,285 | 22,849,062 |
kWh
|
$0.033 |
Natural Gas | $16,546 | 5,212 |
MMBtu
|
$3.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,912 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,391 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $12,917 | $1,500 |
$12,917
396,835
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $9,435 | $200 |
$9,435
289,859
kWh
|
|
03 | 2.3212: Optimize plant power factor | $20,507 | $33,600 |
$20,507
-
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,107 | $1,966 |
$1,107
33,998
kWh
|
|
05 | 2.4312: Improve lubrication practices | $8,748 | - |
$8,748
268,757
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,643 | $4,359 |
$2,643
81,184
kWh
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,326 | - |
$1,326
40,739
kWh
|
|
08 | 2.6121: Reduce hot water temperature to the minimum required | $229 | - |
$229
7,034
kWh
|
|
TOTAL RECOMMENDED | $56,912 | $41,625 |
$56,912
1,118,406
kWh
|
||
TOTAL IMPLEMENTED | $11,391 | $4,359 |
$11,391
349,941
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs